Human VE-Cadherin (Vascular Endothelial Cadherin) ELISA Kit
Target Information | |
---|---|
Target Name | VE-Cadherin (Vascular Endothelial Cadherin) |
UniProt ID | P33151 |
Synonyms | CDH5, 7B4, CD144, Cadherin 5 Type 2 |
Product Properties | |
---|---|
Prize | Online Inquiry |
Reactivity | Human |
Assay Type | Sandwich-ELISA |
Assay Time | 3.5 h |
Detection Range | 31.25-2000 pg/mL |
Sample Type | Serum, plasma and other biological fluids |
Sample Volume | 100 μL |
Sensitivity | 18.75 pg/mL |
Specificity | This kit recognizes Human VE-Cadherin in samples. No significant cross-reactivity or interference between Human VE-Cadherin and analogues was observed. |
Research Area | Cancer, Cardiovascular, Signal Transduction |
Reproducibility | Both intra-CV and inter-CV are < 10%. |
Precision | Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level human VE-Cadherin were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level human VE-Cadherin were tested on 3 different plates, 20 replicates in each plate. |
Storage | -20 ℃. Please refer to the instructions for details. |
Application
This ELISA kit applies to the in vitro quantitative determination of Human VE-Cadherin concentrations in serum, plasma and other biological fluids.
Test Principle
This ELISA kit uses the Sandwich-ELISA principle. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to human VE-Cadherin. Standards or samples are added to the micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for human VE-Cadherin and Avidin-Horseradish Peroxidase (HRP) conjugate are added successively to each micro plate well and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain human VE-Cadherin, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of stop solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The OD value is proportional to the concentration of human VE-Cadherin. You can calculate the concentration of human VE-Cadherin in the samples by comparing the OD of the samples to the standard curve.
! For research use only. Not intended for any clinical use.